BACT/ALERT® Culture Media Bottles
High proven performance & Optimized formula Culture Media
BACT/ALERT® culture media offers a comprehensive range of media bottles to ensure the recovery of a wide variety of microorganisms (bacteria, mycobacteria, and fungi) – including our next generation Fastidious Antimicrobial Neutralization Plus media (FAN® PLUS) offering optimized time to detection and recovery. 1,2,3
Disclaimer: Product availability varies by country. Please consult your local bioMérieux representative for availability in your country.
- BACT/ALERT Culture Media
- Overview
- Bottles
- Services & Support
- Specs & Resources
Overview
Blood culture bottles designed for every clinical need
BACT/ALERT® Culture Media provide an optimal environment for microbial growth, enabling detection and recovery of a wide range of microorganisms, including bacteria, fungi, and mycobacteria. Flexible media recovers organisms from many sample types from blood to sterile body fluids.
BACT/ALERT® Culture Media offer:
- Enhanced performance: optimal growth for fast and accurate results
- Reliable media quality: multilayer shatterproof plastic bottles with a unique gas barrier that helps maintain media stability
- Three bottle types: streamlined workflow with aerobic, anaerobic, and pediatric bottles. Specialized bottles : MP bottle for Mycobacteria detection in non-blood samples
- 24-hour delayed entry: flexible bottle management & transport
- Colorimetric technology: a visual growth indicator with a noticeable & permanent color change, eliminating the risk of false negatives in case of delayed incubation
- Fill-to marks: guide optimal blood volume collection to support blood culture sample collection practices in clinicial wards.
The BACT/ALERT® FAN® PLUS advantage:
Earlier Stewardship decisions for Bloodstream Infections Management (BSI)
Optimized Microorganism Recovery
- Best antimicrobial neutralization performance for reliable BSI detection4-8
- Effective organism recovery and growth detection in blood and sterile body fluids, with or without supplementation
- Early positive signal detection under delayed entry conditions
- Advanced high-capacity resin technology for effective antimicrobial neutralization
1. Qin et al., (2025). Comparative evaluation of BacT/ALERT VIRTUO and BACTEC FX400 blood culture systems for the detection of bloodstream infections. Microbiology Spectrum.
2. R.Amarsy-Guerle et al, (2015). High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care. Eur J Clin Microbiol Infect Dis.
3. Halperin et al. (2022). Impact of Automated Blood Culture Systems on the Management of Bloodstream Infections: Results from a Crossover Diagnostic Clinical Trial. Microbiology Spectrum.
4. Hang Y. et al. (2024). Comparison of antimicrobial neutralization across three culture media. Microbiology Spectrum.
5. Lovern D. et al. (2016). Antimicrobial binding and growth kinetics in FA Plus vs. BACTEC Aerobic/F Plus media. Eur J Clin Microbiol Infect Dis.
6. Xu et al., (2021). Inactivation of Clinically Frequently Used Antimicrobial Agents by BacT/ALERT FAN Plus and BACTEC Aerobic and Anaerobic Culture Media in Simulated Blood Cultures: First Comparative Evaluation in China Mainland. Infection and drug resistance.
7. Chung et al., (2019). A comparative evaluation of BACT/ALERT FA PLUS and FN PLUS blood culture bottles and BD BACTEC Plus Aerobic and Anaerobic blood culture bottles for antimicrobial neutralization. Eur J Clin Microbiol Infect Dis.
8. Menchinelli et al., (2019). Efficient Inactivation of Clinically Relevant Antimicrobial Drug Concentrations by BACT/ALERT® or BACTEC™ Resin-Containing Media in Simulated Adult Blood Cultures. Antimicrobial Agents & Chemotherapy.
Bottles
Standard Bottles
Our standard media recovers microorganisms from many sample types, including blood and sterile body fluids.
| Bottle Type | Media Formulation | Specimen Type | Specimen Volume |
|---|---|---|---|
| BACT/ALERT® SA Standard Aerobic - Ref. 259789 | 40 ml supplemented tryptic soy broth (TSB) | Blood or normally sterile body fluid (SBF) | Up to 10 ml |
| BACT/ALERT® SN Standard Anaerobic - Ref. 259790 | 40 ml TSB | Blood or SBF | Up to 10 ml |
Fastidious Antimicrobial Neutralization Plus Media (BACT/ALERT® FAN® PLUS)
Offering optimized time to detection and recovery, BACT/ALERT® FAN® PLUS bottles provide clear Gram stains and the absorbent polymeric beads offer antimicrobial neutralization.
| Bottle Type | Media Formulation | Specimen Type | Specimen Volume |
|---|---|---|---|
| BACT/ALERT® FA PLUS - Ref. 410851 | 30 ml of supplemented complex media containing adsorbent polymeric beads | Blood or normally sterile body fluid (SBF) | Up to 10 ml |
| BACT/ALERT® FN PLUS - Ref. 410852 | 40 ml of supplemented complex media containing adsorbent polymeric beads | Blood or SBF | Up to 10 ml |
| BACT/ALERT® PF PLUS - Ref. 410853 | 30 ml of supplemented complex media containing adsorbent polymeric beads | Blood | from 0.1 mL up to 4 ml |
Mycobacterium Bottles
| Bottle Type | Media Formulation | Specimen Type | Specimen Volume |
|---|---|---|---|
BACT/ALERT® MP Mycobacteria Process - Ref. 419744 Use with Ref. 414997 | 10 ml supplemented Middlebrook 7H9 broth | Processed specimen or SBF other than blood | 0.5 ml |
Platelet QC Testing
| Bottle Type | Media Formulation | Specimen Type | Specimen Volume |
|---|---|---|---|
| BACT/ALERT® BPA Aerobic Platelet culture bottles - Ref. 279018 or EU Ref. 279044 | 40 ml supplemented tryptic soy broth (TSB) | Leukocyte reduced apheresis platelet (LRAP) units, and both leukocyte reduced single and a pool of up to six (6) units of leukocyte reduced whole blood platelet concentrates (LRWBPC) | 4-10 ml |
| BACT/ALERT® BPN Anaerobic Platelet culture bottles - Ref. 279019 or EU Ref. 279045 | 40 ml supplemented tryptic soy broth (TSB) | Leukocyte reduced apheresis platelet (LRAP) units, and both leukocyte reduced single and a pool of up to six (6) units of leukocyte reduced whole blood platelet concentrates (LRWBPC) | Up to 10 ml |
Accessories and Devices
Blood Collection
| Product | Description | Packaging |
|---|---|---|
| SampLok® Adapter Cap 3 - Ref: A100760 | Screw tread for luer and blood collection needle collection | 600 per case |
SampLok® Adapter Cap 3 Insert - Ref: A100761 To be used with Ref: A100760 | Optional insert for use with vacuum tubes and long-neck culture bottles | 840 per case |
| VACUETTE® Blood Culture Holder - Ref: 450181 | Neck design accommodates evacuated tubes without the need for an insert (female threaded luer) | 320 per case |
Post-analytic Devices
| Product | Description | Packaging |
|---|---|---|
| Sterile Airway Needle - Ref: 233766 | For venting aerobic blood culture bottles & subculturing blood culture bottles | 100 per case |
| SampLok® Safety SubCulture Unit - Ref: A100720 | Transfer measured samples using needleless syringe | 360 per case |
| SampLok® Safety SubCulture Unit 2 - Ref: A100722 | Needleless transfer onto slides or media plates | 288 per case |
| Transfer Cap Set - Ref: A100730 | Transfer from culture bottle to vacuum tube | 180 per case |
Services & Support
- Performance validation pack including blood culture analysis and seeded protocol for onsite validation testing
- Hands-on training course
- Remote hotline knowledge center support
- Onsite expert system engineer for instrument follow-up & maintenance.
Specs & Resources
Specifications
bioMérieux was the first to introduce revolutionary multilayer plastic bottles. Made of multi-layers design ensuring the appropriate environement for recovery of microorganisms.
- Shatter-resistant bottles reduce potential for biohazard exposure
- Up to 2/3 lighter than glass, allowing cost effective disposal
- Adapt to a variety of protocols and enable pneumatic transport without a special container